# University of Houston: Telecommunication infrastructure standards

> Telecommunication Infrastructure Standards prepared by IT Network Operations, revision 1.17, revision date March 2012. Establishes one campus’s labeling appendix: copper patch cords labeled with the switch and port number on the patch panel end and the patch panel and port number on the switch end; outside plant fiber labeled at each end with the far-end building name and number, mode and strand count, placed between 12 and 36 inches from a conduit and at 200-foot intervals along its run; riser fiber labeled on both ends with the far-end room number, strand count and mode. The document describes itself as a minimum standard and a starting point for collaboration, and names TIA/EIA-568-B and TIA/EIA-606-A, both superseded editions, so it is cited as a dated worked instance rather than as current requirements. Checked September 16, 2026.

Canonical page: https://datacenterlabeling.com/references/s76

Original source: [University of Houston: Telecommunication infrastructure standards](https://uh.edu/infotech/_documents/UHCablingStandardsrev1.17.pdf)

## Scope of this source

Telecommunication Infrastructure Standards prepared by IT Network Operations, revision 1.17, revision date March 2012. Establishes one campus’s labeling appendix: copper patch cords labeled with the switch and port number on the patch panel end and the patch panel and port number on the switch end; outside plant fiber labeled at each end with the far-end building name and number, mode and strand count, placed between 12 and 36 inches from a conduit and at 200-foot intervals along its run; riser fiber labeled on both ends with the far-end room number, strand count and mode. The document describes itself as a minimum standard and a starting point for collaboration, and names TIA/EIA-568-B and TIA/EIA-606-A, both superseded editions, so it is cited as a dated worked instance rather than as current requirements. Checked September 16, 2026.

Cited for what one owner specified in 2012, including a reciprocal patch cord rule stated in a single sentence. No compliance outcome is inferred, and its cited standard editions are superseded.

Rackstamp provides editorial field guidance. IDs, cases, and worksheet entries are fictional examples unless identified otherwise. Distinguish local conventions from adopted standards. Source notes describe the evidence scope; a linked overview is not the full standard or a project approval.