Use it with your own records.
- Download the workbook and open 23 Print quality.
- Enter your site and room scope and the project or policy reference.
- Use the blank amber table for actual records. The fictional example below it is a reference.
- Insert table rows when needed. Keep identifiers as text, including leading zeros.
- Follow guide 23 to complete the checks and record unresolved items.
Before you start
- Preserve the approved source, actual preview, and failed output so the earliest stage of divergence can be identified.
- Identify the printer unit, resolution, software path, template revision, loaded stock, and ribbon or ribbonless process.
- Gather the model-specific setup and supply instructions, a known accepted comparison proof, and the current configuration reference.
- Hold uncertain production under a batch reference and keep troubleshooting proofs distinct from installable output.
Complete the register
- Assign a Proof ID to each physical sample and record its batch or sequence position when that helps explain drift or interruption.
- Enter the actual Printer and Template revision, including the relevant workstation or export path when outputs differ.
- Record Media and Ribbon from exact references, checking the supported complete combination rather than appearance alone.
- Link each Settings reference to the actual configuration and describe the one changed factor or complete authorized procedure between proofs.
- Write Proof result as separate content, placement, print-integrity, and agreed handling observations, retaining failures as well as successes.
- Link Evidence, Owner, and Verification date to the accepted repeat sequence and the disposition of affected earlier production.
Walk through the example
In fictional DC01 / H1, proof P-01 shows a clipped rightmost digit while the approved source identifier remains unchanged. Record the actual printer and supply references rather than copying the worksheet's fictional device details into a live job. The reviewer compares the loaded stock with the selected template and documents the corrected stock template used for P-02. Enter the changed configuration reference and retain the rejected proof as evidence. P-03 repeats the accepted setup and produces complete, stable output in the reviewed sequence. The worksheet's example 300 dpi resolution and stock dimensions describe its fictional setup; they are not recommended settings for other printers. Record the actual handling observation, reviewer, and verification date. Finally, identify which earlier copies were held or voided and which verified faces are released. Saving the template does not complete that physical accounting or establish that installed labels were later placed on the right objects.
Handle common exceptions
The preview already omits a required character.
Resolve source mapping or layout first and preserve the before-and-after values; printer adjustment cannot restore text absent from the rendered job.
A print job stops and its last physical output is uncertain.
Hold the uncertain range, reconcile available sequence evidence, and obtain the batch owner's specific resume or reprint instruction.
A replacement printer restores production while the old unit remains faulty.
Release the newly proved setup and track the old unit's maintenance separately, preserving both configuration histories.
Review and close
- Confirm that longest legends, first and last fields, and any symbol remain complete within the actual printed layout.
- Check the reviewed repeat sequence for placement stability and record the actual start, later, and end observations.
- Ensure the release reference includes the supplies and output path needed to reproduce the accepted proof.
- Reconcile held, voided, reprinted, and issued output with the batch owner, including uncertain copies from interruptions.
- Attach separate symbol/payload checks where needed and retain unresolved printer maintenance as a distinct open obligation.
Fields and filled example
Fictional values only. Scope: DC01 / H1 unless another location is shown. The downloadable register is blank for your actual observations.
| Field | What to record | Fictional example |
|---|---|---|
| Proof ID | Reference for the physical sample. | P-03 |
| Printer | Model, unit reference, and resolution. | Example printer P1; 300 dpi |
| Template revision | Exact layout used. | Cable-wrap r3 |
| Media | Label stock part and size. | Example stock B; 40 x 25 mm |
| Ribbon | Qualified part or explicit not-applicable. | Example ribbon B |
| Settings reference | Saved setup including speed/density. | EX-P1-config-r2 |
| Proof result | Legibility, placement, and handling findings. | Complete; stable on repeat |
| Evidence | Sample or photograph reference. | EX-P03 |
| Owner | Person accepting the print setup. | Example print reviewer |
| Verification date | Date of physical proof review. | 2026-09-12 |

Sources and scope
- Brady: Ribbon and label compatibility ↗
Manufacturer guidance on qualified combinations and print durability.
Read scope and linked guides - Zebra: Adjusting print quality ↗
ZD421/ZD621-specific guidance; settings are not universal.
Read scope and linked guides